Heh. "FEC" = Forward Error Correction. MTS uses it. They probably shouldn't in most cases, or rather: not so aggressively.
For every 100 bits of user data your DSL modem transmits (or receives), it also sends anywhere between 1 and 50 bits of EDAC (error detection and correction) data. The particular schemes used in ADSL are collectively referred to as FEC, and typically convolutional Trellis Coding is combined with Reed-Solomon block coding.
The The DSL Forum Technical Report TR-63 (addendum to TR-57) clarifies that in general DSL management systems may specify - independently - upstream and downstream FEC overhead between 1% and 50%.
I don't recall where MTS has it set usually, but I do recall that it's substantial. And on slower connections (e.g. the <1Mbps upstream connection) adding that much overhead *can* introduce noticeable latency. In theory, it shouldn't be double, but implementation details can alter that assumption.
The reason FEC is used is the same reason ARQ was added to modems back in the 2400baud days - phone lines are "noisy". We aren't talking Cat6 cable here, we aren't even talking Cat3, which is generally what gets run inside a building for telephone use. We're talking a single pair of copper wires, often with no twist whatsoever, sometimes both in direct contact with the ground (which does *not* provide infinite electrical resistance, i.e. it's a partial short), sometimes with "load coils" (don't ask if you don't already know!)... basically a worst-case scenario for data transmission.
Without FEC, so many packets would be discarded that your DSL line would be completely useless. Ever try to download a file when you're getting 10% packet loss? Try it at 90% packet loss. Good luck :-). So the bottom line is, MTS errs on the side of reliability over performance.
HOWEVER: the FEC parameters are tunable on a per-modem basis, and the upstream and downstream knobs are independent. Does MTS implement this? I know they sure didn't the last time I had anything to do with their OA&M systems (about 6 years ago). The telco (ILEC, but not MTS) I do work with now certainly doesn't - because management systems that can tune those knobs intelligently and automatically are !#@$%^&* expensive, and it's just too much work to do manually.
If Les has convinced MTS to reduce the FEC overhead, you'll get a speed improvement of UP TO 50%, and a latency decrease of UP TO 50%. (Anything beyond 50% indicates non-standard implementation.) On the other hand, if Les didn't actually ask for that, I have to wonder if MTS is turning FEC back down to the minimum in order to make Les' service appear less reliable??? Considering some of the anti-competitive behaviour they exhibit (not quite illegal, though) it wouldn't surprise me.
FWIW, previous generations of ADSL equipment typically had FEC as an on/off switch, not a controllable parameter. And Sean and I probably share the same information sources inside MTS, from several years ago... And since I don't work there anymore, and I don't know the details of their DSLAMs, anything I've said here might be inapplicable or just plain wrong.
-Adam
-----Original Message----- From: roundtable-bounces@muug.mb.ca [mailto:roundtable-bounces@muug.mb.ca] On Behalf Of Dan Keizer Sent: Tuesday, July 13, 2010 15:55 To: Continuation of Round Table discussion Subject: Re: [RndTbl] Request confirmation...
I used to be on MTS with their DSL, but went to les.net as he provides better options for what I would like -- and when I switched to les, my speed doubled and my RTT went in half -- obviously MTS didn't have things setup properly - I was even told from MTS at one point that the loop length may have been an issue -- but, obviously it was not. Good thing I switched as I now have a nice full-speed DSL line :-) I also have my VoIP hosted with les.net -- can't get better than that --